Discusión entre pares / 25 yr male 7 day old Rt Volar barton frac. Done without C-arm, Critical comment please
Alok Choudhary
Indian Orthopaedic Research Group
25 yr male 7 day old Rt Volar barton frac. Done without C-arm, Critical comment please
Me gusta
Drvinod Rajkumar
kindly post a proper ap and lat view
4 horas
·
Me gusta
·
1
Neeraj Kharub
I never thought of C ARM for this
4 horas
·
Me gusta
·
1
Neeraj Kharub
The fixation looking a little flimsy please provide adequate protection
4 horas
·
Me gusta
Alok Choudhary
is not plate a little bit proximal
4 horas
·
Me gusta
·
2
Parthiv Raval
How was hold of distal screws?
4 horas
·
Me gusta
Neeraj Kharub
I think l am a little too humble not to say that
4 horas
·
Me gusta
·
1
Alok Choudhary
hold is good, used locking lcp
4 horas
·
Me gusta
·
1
Neeraj Kharub
The job is going to be done
4 horas
·
Me gusta
Alok Choudhary
wrist movement looks good on ot table, after fixation
4 horas
·
Me gusta
Farhan Syed
If those radiographs were taken at your own hospital, then the radiographer doesn't deserve a salary. If they were done elsewhere then please stop sending your patient there and wasting their money.
The wrist is not centred. They are oblique views that are of no use assessing the radiological parameters.
4 horas
·
Editado
·
Me gusta
·
7
Alok Choudhary
sorry for Xray fault of technician
4 horas
·
Me gusta
Neeraj Kharub
Shed bhai ab itni bhi mat lo bhai ki
4 horas
·
Me gusta
Faguram Majhi
Gud job
3 horas
·
Me gusta
Mohamed Ammar
the AP is nt AP and the lat is nt lat
3 horas
·
Me gusta
·
2
Manpal Narula
Not using a c-arm should not be an alibi in today's wrld. Had you used image , the plate could /should have been more distal ..and of course if you posting your 'well done' xrays for comments/complements , xrays have to be right too! !
3 horas
·
Me gusta
·
1
Kaushlendra Kumar
Plate is too proximal.
It's a common mistake done by younger surgeon's , specially if C - arm is not used.
2 horas
·
Me gusta
·
2
Kir Pat
This plate is antiglide function mainly and even no screw in distal frg has also been mentioned , so perop view of extent of plate in distal frg upto near its watershed edge only is enough by vision (as it,s approach to PQ) ,I think fluro is needed for intraarticular screw penetration only..other wise not.
1 hora
·
Me gusta
Alok Singh
One rarely uses c arm in volar plating
1 hora
·
Me gusta
Kaushlendra Kumar
I regularly use C - arm at the time of final positioning of plate. Just 2-3 shots needed.
1 hora
·
Me gusta
·
1